In this article I will explain the normal fundamental requirements of a sound, modern-day high stress, straight installation. The adhering to description relates to a contemporary high pressure (400/600Kpa) system commonly made by Kwikot South Africa.

geyser installationgeyser installation


Much less usual are old reduced stress systems (100kpa) open pipe or "Latco" kind systems. Understand that the parts are NOT compatible between both distinct systems - High stress and also Low stress! It is possible to eliminate an old reduced pressure system and also change it with a modern high pressure system however - you get a brand-new high pressure geyser and mount it according to the current requirements.



The very same regulations use but there are some special factors to consider described at the end - with a diagram. picture kwikot - One of the most evident point that you should see right away. The hot spring beings in a tray made from plastic (often red) or tin plate. I favor the plastic ones.

Because June 2001, the drip tray is not optional - its reached be there and also there has to be a drain pipeline for it! The drain is a 50mm PVC waste pipeline that drains pipes the tray by piping the water out your home. I have seen several drip trays set up without drains! If your installment pre-dates June 2001 you might wish to get a plumbing professional to consider it.

Top Guidelines Of Geyser Installation

The two vacuum breakers stand vertically about 30cm over the hot spring. These are crucial, as they quit water siphoning out the hot spring when the cool supply is stopped - geyser installation.

Keep in mind that vacuum breakers are a sensibly new need - there are still thousands of old HP systems out there without vacuum cleaner breakers and I am yet to see one collapse. Simply due to the fact that I have not seen it doesn't indicate it's not taking place!

The cold water side is the side that straight connects to the drainpipe cock as well as goes into the hot spring at the base. After the shut off valve you would normally locate a Pressure Control Valve (PCV). There are a variety of different kinds, mostly constructed from brass yet some are made of plastic.

This is where the PCV releases pressure and this is the pipeline that frequently trickles. Do not stress if you can not find the PCV next to the hot spring - it may be placed up to 10 metres away, frequently in a much more obtainable put on a wall surface outside. Occasionally it remains in a little plastic box exterior.

Things about Geyser Installation

This shutoff must have a steel (copper or steel) pipe linked to it and also the pipe should lead directly out the building. This vent pipeline is an important safety and security feature of the entire system.

The T&P shutoff is the least optional part - it has to be there! - The weight of the geyser have to be effectively supported on the roofing system trusses - a minimum of two assistances under the 'feet' of the hot spring. If it looks shaky get a plumber to inspect click for source it out.

The hot spring has to be earthed! I have seen several hot springs with the earth wire inapplicable. All the copper pipes have to also be earthed as well as bonded to the hot spring earth.


Again, these are frequently simply left lying following to the hot Full Article spring. There are essentially just two primary thermostat kinds - the modern round "Kwiktherm" in more recent Kwikot geysers and the VK (rectangle-shaped block) type in older geysers as well as in some newer non-Kwikot units. The geyser might be fed (cold water) with polcop (plastic) pipeline - as much as the shut down shutoff, but the pipeline into and out of the geyser have to be copper or galvanized steel.

Top Guidelines Of Geyser Installation

geyser installationgeyser installation


The warm water side ought to be copper, steel or appropriately rated (70) plastic or composite pipeline. Keep in mind that you have to have at the very least 1m of copper/steel pipe out the hot spring - you may not connect plastic (composite) pipeline straight to the geyser. As above, the PCV and T&P need to be constructed from copper or steel - particularly the vent out of the T&P valve.

geyser installationgeyser installation


I have actually seen a variety of setups where the installer has simply run a brief size read here of 22mm copper into the drip tray with the concept being that the T&P can air vent directly right into the drip tray. A concept since the hot (100 +) water/steam thaws the drip tray as well as the PVC drainpipe pipe.

The PCV is generally over the hot spring and also the cool water streams down right into the hot spring. This is quite important due to the fact that it creates an anti-syphon loop that avoids the hot spring from draining pipes back through the inlet in the occasion of a water failure. If you obtain hot water appearing your cold faucets when the water system falls short then this is not functioning appropriately.